• Despite Appearances
    THIS IS BIG
  • Retropulsion
    Is So Retro
  • Plugging It In Is a
    One-Person Job
   

The new SOLTIVE™ SuperPulsed Laser systems delivers exceptional performance in a surprisingly small and versatile package.

  • Olympus pioneered a novel energy source for bringing striking performance compared to high-powered Holmium YAG1
  • Our urology fibers are the smallest and most flexible fibers at highest power output as compared to market leading urology fibers1

SOLTIVE™ SuperPulsed
Laser System Premium includes:

2x faster lithotripsy with less power5

Incredibly fast dusting, double the speed of leading holmium YAG laser with impressive generation of fine particulate.

Highly versatile, all-in-one platform

BPH treatment with state-of-the-art prostate enucleation and visibly improved hemostasis7 for surgery centers seeking all-in-one, cost-effective platform.

Virtually no retropulsion6

Inherent stone stabilizing effect without the need for specialized fibers or costly software upgrades.

1/8th the size of competing systems5

Compact design for greater O.R. efficiency.

Plugs into any standard wall outlet

Because it requires no specialty wiring, SOLTIVE SuperPulsed Laser can be used in any O.R. suite.

Quiet operation9

Cooled by air, and designed with modern components, SOLTIVE SuperPulsed Laser offers quiet operation and low cost maintenance.


Olympus Total Lithotripsy Solution
  • Only one company can bring stone management full circle. Treat stones from above with Shockpulse-SE and from below with SOLTIVE™.
  • Complete with a convenient cart designed to hold both systems.
PCNL ShockPulse-SE | fURS SOLTIVE & URF-V3

SOLTIVE™ SuperPulsed Laser Technology
Smallest and most flexible fibers at highest power output as
compared to market leading urology fibers2

True-to-size 150u and 200u core diameter fibers for access to hard-to-reach stones.

150u fiber offers 32% more irrigation3 for better visibility.

150u fiber offers better flexibility and minimized scope deflection loss as compared to 200u and larger fibers.

150u fiber can deliver nearly triple the power of competitor’s small fibers4.

Effective treatment at lower power means reduced fiber burn back5 and may eliminate the need for multiple fibers or cutting and cleaving of fibers mid-procedure.

Easy “quick-connect” - no twisting or screwing.

Convenient color coding to easily identify type and size

Join the Conversation
Available on the AppStore

Using the latest in augmented reality technology, experience Olympus’ SOLTIVE™ SuperPulsed thulium fiber laser for stone lithotripsy procedures.

DOWNLOAD

Clinical Information

SOLTIVE™ SuperPulsed Laser
Learn from the globally recognized thought leader in Ureteroscopy, Professor Olivier Traxer who outlines the difference between the dated Holmium technology and new cutting edge TFL technology. See the SOLTIVE™ difference and learn why “this changes everything”.
Play Video
Play Video
The Future of Lithotripsy: SOLTIVE™ SuperPulsed Thulium Fiber Laser
Watch Dr. Bodo Knudsen, Director, Comprehensive Kidney Stone Program The Ohio State Wexner Medical Center as he discusses his clinical experience with the next great innovation in Urology surgery.
Redefining Laser Versatility & Performance
What happens when you put the cutting edge of endourology laser technology in the hands of one of the world’s most versatile endourologists? Learn from Dr. Mantu Gupta of Mt. Sinai West Hospital in New York City in this webinar where he discusses his experience across stone, BPH & soft tissue cases with the SOLTIVE™ laser.
Play Video
Play Video
Future of Prostate Enucleation: SOLTIVE SuperPulsed Laser with Dr. Naeem Bhojani
World-renowed endourologist and Associate Professor at the University of Montreal Dr. Naeem Bhojani discussions his case experience, strong outcomes and advantages of the SOLTIVE SuperPulsed Laser over Ho:YAG for prostate enucleation.

Clinical Evidence

Several published studies introducing SOLTIVE™ SuperPulsed Thulium Fiber Laser technology capabilities to the market, and highlighting competitive advantages of the technology:
Meeting Title / Topic Lead HCP
Journal of Urology, September 2021 HO:YAG versus TFL (SOLTIVE) for the Treatment of Upper Urinary Tract Calculi in Dusting Mode: A Clinical Comparison of Efficiency, Efficacy and Costs Effectiveness Dr. Ahmed Ghazi
Journal of Urology, September 2021 Thulium Fiber Laser Results in Shorter Operating Times During Ureteroscopy and Laser Lithotripsy Dr. Johann Ingimarsson
World Journal of Urology, September 2021 Operating room noise hazards during laser lithotripsy: a comparison between the thulium fiber and holmium laser platform Dr. Jonathan Moore
AUA 2020 Low Power Cutting using SOLTIVE SuperPulsed Thulium Fiber Laser: Comparison with Ho:YAG Dr. Ben Chew
AUA 2020 Comparison of Small Core Diameter Laser Fibers Used for Lithotripsy with a 120W Ho:AG Laser and the SOLTIVE SuperPulsed Thulium Fiber Laser Dr. Bodo Knudsen
AUA 2019 Temperature rise during Laser Lithotripsy: Comparison of Super Pulse Thulium Fiber LASER (SPTF) vs High Power 120W Holmium-YAG LASER (Ho:YAG) Dr. Wilson Molina
AUA 2019 Comparison of dusting and fragmenting using the new Super Pulse Thulium Fiber Laser to a 120W Holmium:YAG laser Dr. Ben Chew
AUA 2019 Super Pulse Thulium Fiber Laser Compared to 120W Holmium:YAG Laser: Impact on Retropulsion and Laser Fiber Burn Back Dr. Bodo Knudsen
WCE 2019 Temperature rise during Laser Lithotripsy: Comparison of Super Pulse Thulium Fiber LASER (SPTF) vs High Power 120W Holmium-YAG LASER (Ho:YAG) Dr. Wilson Molina
WCE 2019 Comparison of dusting and fragmenting using the new Super Pulse Thulium Fiber Laser to a 120W Holmium:YAG laser Dr. Ben Chew
WCE 2019 Super Pulse Thulium Fiber Laser Compared to 120W Holmium:YAG Laser: Impact on Retropulsion and Laser Fiber Burn Back Dr. Bodo Knudsen
WCE 2019 Hemostatic properties of Super Pulse Thulium Fiber (SPTF) LASER: Comparison with High Power 120W Holmium-YAG LASER (Ho:YAG) in an ex-vivo Porcine Kidney Model Dr. Wilson Molina
WCE 2019 Tissue incision, excision and ablation using Super Pulse Thulium Fiber (SPFL) LASER: Comparison with High Power 120W Holmium-YAG LASER (Ho:YAG) Dr. Ben Chew
WCE 2019 Comparison of Small Core Diameter Optical Laser Fibers Used for Holmium:YAG and Super Pulse Thulium Laser Lithotripsy Dr. Bodo Knudsen
WCE 2018 Comparison of Rapid-Pulse Tm Fiber LASER (RPFL) vs High Power 120W Holmium-YAG LASER (Ho:YAG): Stone ablation efficiency at the same average power settings Dr. Wilson Molina

Education Opportunities

Olympus Professional Education offers a vibrant and immersive learning experience led by experts in medical technology, procedural innovations, and patient care. Learning and training opportunities include hands-on courses, online learning, lectures and workshops, peer-to-peer training, accredited continuing education, and custom on-demand learning as well as a vast library of educational resources.

LEARN MORE

Read press releases, latest news and download images on our
Olympus Medical Media Center
LEARN MORE

Sign-Up

Want to learn more about SOLTIVE and receive Urology updates from Olympus?

The SOLTIVE SuperPulsed Laser, powered by a novel energy source, is capable of dusting stones in half the time and fragmenting stones relentlessly with virtually no retropulsion. For effective dusting and fragmentation, the tip of the laser fiber should be directly in contact with the stone. Continuous irrigation should be used to wash away stone fragments and to provide cooling of the treatment site. The use of higher power settings should be avoided, especially when the fiber tip is in close proximity to the ureteral wall, as perforation of the ureter may result. As with non-laser surgery, the possibility of complications and adverse events, such as chills, fever, edema, hemorrhage, inflammation, tissue necrosis, or infection may occur following treatment. In extreme cases, death may occur due to procedural complications, concurrent illness, or laser application. As with any conventional surgery, acute pain may occur immediately following laser therapy and may persist for as long as 48 hours. For further information please refer to the SOLTIVE Laser System IFU - PN0015551_AE.

Disclaimer
1. All claims based on non-clinical laboratory testing using synthetic stones (Begostones) in a simulated environment
2. Data on file. Comparative fiber data collected with Cook 150, Lumenis 230 and EMPOWER 200 core diameter fibers
3. Compared to 200u fibers. Data on file.
4. Data on file. Comparative fiber data collected with Cook 150.
5. Data on file. Comparative laser system data collected on Lumenis P120.
6. At select settings. Data on file compared to Lumenis P120.
7. Data on file. Compared to Lumenis P120. Improved hemostasis noted at 365um diameter fibers & larger. Data is not from a clinical Study.
8. Data on files. Testing conducted with Begostones.
9.Data on file with Olympus. DN0040298_01 Technical Memo SOLTIVE v P-120 Sound Testing